MODIS Instrument Operations Team Health and Status


Below is the most recent listing of the current operational state of the MODIS Instruments.

For an explanation of the items and their values listed in the table below, please read the explained health and status page.


AM-1 "Terra" MODIS (PFM) PM-1 "Aqua" MODIS (FM1)
AM-1 "Terra" is in Normal Mode
PFM MODIS is in A-Side Nominal Science Mode
(Cross Strapped with FR B)
Component State(s) Comment
Blackbody A On (290K); B Off Nominal Science Mode
Calibration ElectronicsA On; B Off Nominal Science Mode
Control Processor A On; B Off Nominal Science Mode
Nadir Door Unlatched, Open Nominal Science Mode
Space View Door Unlatched, Open Nominal Science Mode
Solar Diffuser Door Unlatched, Screened Permanent Configuration
FDDI Formatter A On; B Off Nominal Science Mode
FDDI Port A On; B Off Nominal Science Mode
FIFO Memory #1 & #2 On; #3 & #4 OffNominal Science Mode
Format Processor A Off; B On Nominal Science Mode
Power Supplies #1 On, #2 Off Nominal Science Mode
PV VIS FPA A On; B Off Nominal Science Mode
PV NIR FPA A On; B Off Nominal Science Mode
PV SMIR FPA A On; B Off Nominal Science Mode
PV LWIR FPA A On; B Off Nominal Science Mode
PC LWIR FPA A On; B Off Nominal Science Mode
RC Outgas Heaters All 3 (CS, IS, OS) Off Nominal Science Mode
RC LWIR FPA Heater On (83K) Nominal Science Mode
RC SMIR FPA Heater Off Nominal Science Mode
Scan Assembly A On; B Off Nominal Science Mode
SDSM Off Nominal Science Mode
SRCA Off
  • 10W Lamps - 1, 4 (functional)
  • 10W Lamps - 2, 3 (non-functional)
  • 1W Lamps - 1, 2 (functional)
Nominal Science Mode
PS1 Survival Heater Enabled Nominal Science Mode
PS2 Survival Heater Enabled Nominal Science Mode
Timing Generator A On; B Off Nominal Science Mode
Flight Software Rev BD + 11 sets of patches
  • CP07 to Survival Mode - No SDD to closed command (1 patch)
  • CP07 to Safe Mode - No FR OFF Command (1 patch)
  • CP07 to Safe Mode - No SDD to closed command (1 patch)
  • CP07 to Science Mode - Turn on FRB instead of FRA (1 patch)
  • CP07 to Outgas and Science Mode - Turn on FRB instead of FRA (1 patch)
  • FR Error Counting and Statistics (2 patches)
  • FR 1000ms time code patches (3 patches)
  • FR Band 5 Gain Change (20 commands)
  • FR BB Ideal Output Values (1 patch)
  • FR A EEPROM KME Fast 1 word patch (1 patch)
  • FR B EEPROM KME Fast 1 word patch (1 patch)
Nominal Science Mode
Inhibit Ids Set none Nominal Science Mode
TMON 66 Disabled Nominal Science Mode
TMON 67 Disabled Nominal Science Mode
TMON 68 Enabled Nominal Science Mode
TMON 69 Disabled Nominal Science Mode
Table Last Updated: Wednesday, 29-Mar-2006 15:32:59 EST
PM-1 "Aqua" is in Fine Pointing Normal Mode
FM1 MODIS is in B-Side Nominal Science Mode
Component State(s) Comment
Blackbody A Off; B On (285K) Nominal Science Mode
Calibration ElectronicsA Off; B On Nominal Science Mode
Control Processor A Off; B On Nominal Science Mode
Nadir Door Unlatched, Open Nominal Science Mode
Space View Door Unlatched, Open Nominal Science Mode
Solar Diffuser Door Unlatched, Closed Nominal Science Mode
FDDI Formatter A Off; B On Nominal Science Mode
FDDI Port A Off; B On Nominal Science Mode
FIFO Memory #1 & #2 Off; #3 & #4 OnNominal Science Mode
Format Processor A Off; B On Nominal Science Mode
Power Supplies #1 Off, #2 On Nominal Science Mode
PV VIS FPA A Off; B On Nominal Science Mode
PV NIR FPA A Off; B On Nominal Science Mode
PV SMIR FPA A Off; B On Nominal Science Mode
PV LWIR FPA A Off; B On Nominal Science Mode
PC LWIR FPA A Off; B On Nominal Science Mode
RC Outgas Heaters All 3 (CS, IS, OS) Off Nominal Science Mode
RC LWIR FPA Heater Off Nominal Science Mode
RC SMIR FPA Heater On (83K) Nominal Science Mode
Scan Assembly A Off; B On Nominal Science Mode
SDSM Off Nominal Science Mode
SRCA Off
  • 10W Lamps - 1, 4 (functional)
  • 10W Lamps - 2, 3 (non-functional)
  • 1W Lamps - 1, 2 (functional)
Nominal Science Mode
PS1 Survival Heaters Enabled Nominal Science Mode
PS2 Survival Heaters Enabled Nominal Science Mode
Timing Generator A Off; B On Nominal Science Mode
Flight Software Rev BJ + 1 set of patches
  • CP07 to Safe Mode - No FR OFF Command (1 patch)
Nominal Science Mode
Inhibit Ids Set None Nominal Science Mode
Table Last Updated: Tuesday, 12-Jul-2005 13:53:47 EDT

Responsible Civil Servant: Ed Masuoka

Email the MODIS IOT to report any problem with the MODIS IOT Web Pages.