MAIN PAGEMODIS INFOINSTRUMENT OPSWeekly ReportsMODIS HistoryCALIBRATIONL1B PRODUCT INFO
|
MODIS IOT Terra Weekly Report
Mission Operations Days: 2000/316 to 2000/322
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Terra (AM-1) is in Normal Ops Mode MODIS is in Science Mode - B Side |
||
| Component | State(s) | Comment |
|---|---|---|
| Blackbody | A Off; B On (290 K) | Nominal |
| Calibration Electronics | A Off; B On | Nominal |
| Control Processor | A Off; B On | Nominal |
| Nadir Door | Unlatched, Open | Nominal |
| Space View Door | Unlatched, Open | Nominal |
| Solar Diffuser Door | Unlatched, Closed | Nominal |
| FDDI Formatter | A Off; B On | Nominal |
| FDDI Port | A On; B Off | Nominal |
| FIFO Memory | #1 & #2 Off; #3 & #4 On | Nominal |
| Format Processor | A Off; B On | Nominal |
| Power Supplies | #1 Off; #2 On | Nominal |
| PV VIS FPA | A Off; B On | Nominal |
| PV NIR FPA | A Off; B On | Nominal |
| PV SMIR FPA | A Off; B On | Nominal |
| PV LWIR FPA | A Off; B On | Nominal |
| PC LWIR FPA | A Off; B On | Nominal |
| RC Outgas Heaters | All Off (CS, IS, OS) | Nominal |
| RC LWIR FPA Heater | On (83 K) | Nominal |
| RC SMIR FPA Heater | Off | Nominal |
| Scan Assembly | A Off; B On | Nominal |
| SDSM | A Off; B Off | Nominal |
| SRCA | A Off; B Off | Nominal |
| PS1 Survival Heater | Enabled | Nominal |
| PS2 Survival Heater | Enabled | Nominal |
| Timing Generator | A Off; B On | Nominal |
| Flight Software | Rev BD + 1 set of patches
| Nominal |
| Inhibit Ids Set | None | Nominal |
| TMONs Enabled | 68 | Nominal |
None
Sunday, November 12, 2000None
Monday, November 13, 2000None
Tuesday, November 14, 2000None
Wednesday, November 15, 2000
Roll Maneuver:
2000/320 22:15:29 ATC Move Formatter to Night ahead by 3:23 to ensure 50/50 day/night
2000/320 22:41:54 ATC Begin Slew to -11.5456 degrees
2000/320 22:47:43 ATC Set Formatter to Day Rate
2000/320 22:47:45 ATC Set SCIABNORM Flag to ABNORM
2000/320 22:47:47 ATC PC DC Restore to OFF
2000/320 22:47:49 ATC PV DC Restore to OFF
2000/320 22:47:51 ATC Sector Rotation to -3072 (EA to SV and OBCs)
2000/320 22:54:21 ATC Sector Rotation to Zero (Normal)
2000/320 22:54:23 ATC PC DC Restore to ON
2000/320 22:54:25 ATC PV DC Restore to ON
2000/320 22:54:27 ATC Set SCIABNORM Flag to NORM
2000/320 22:54:29 ATC Set Formatter to Night Rate
2000/320 22:59:56 ATC Return to nominal attitude
2000/320 23:11:41 ATC Move Formatter to Day later by 3:23 to ensure 50/50 day/night
None
None
Leonid Meteor shower Nov 17th & 18th: MODIS will remain in nominal B-side science operations, however, all calibration activities will be suspended during this time.
Saturday, November 18, 2000None
Sunday, November 19, 2000None
Monday, November 20, 20002000/325 21:00:00 ATC Set Blackbody to 270K
Tuesday, November 21, 2000
2000/326 15:00:00 ATC Set Blackbody to 280K
2000/326 19:00:00 ATC Set Blackbody to 285K
2000/326 21:00:00 ATC Set Blackbody to 290K
2000/326 23:00:00 ATC Set Blackbody to 295K
2000/326 23:01:00 ATC Set Blackbody duty cycle to FULL
2000/327 01:00:00 ATC Set Blackbody to 300K
2000/327 03:00:00 ATC Set Blackbody to 315K
2000/327 05:00:00 ATC Set Blackbody to 270K
2000/327 05:01:00 ATC Set Blackbody duty cycle to THIRD
2000/328 01:00:00 ATC Set Blackbody to 290K
2000/328 09:48:37 - 10:22:10 ATC SRCA Full Radiometric (B)
2000/329 10:29:10 - 11:20:49 ATC SRCA Full Spectral 30W Part I (B)
2000/329 12:24:17 - 12:59:02 ATC SRCA Full Spectral 30W Part II (B)
2000/329 13:46:23 - 14:37:39 ATC SRCA Full Spectral 10W Part I (B)
2000/329 15:42:04 - 16:20:02 ATC SRCA Full Spectral 10W Part II (B)
None.
No formatter anomalies have been detected since switching to B-side science operations. The MODIS IOT is continuing to monitor changes with the radiative cooler temperatures and focal plane power.
MODIS is in Science Mode on the B-side with the SVD and NAD open, operating with the Formatter Resolution Flight Software Patches (FRFSP). No new events have been witnessed by the FRFSP since the B-Side Transition on DOY 2000/304.
The Radiative Cooler intermediate stage temperature has slowly been increasing since approximately day 2000/240. During this time the LWIR focal plane heater margin has been decreasing. The IOT is continuing to trend these telemetry mnemonics.
None.
SRCA 10W Lamp #1: 173.8 of 500 hours
SRCA 10W Lamp #2: 136.3 of 500 hours
SRCA 10W Lamp #3: 145.5 of 500 hours
SRCA 10W Lamp #4: 61.5 of 500 hours
SRCA 1W Lamp #1: 556.1 of 4000 hours
SRCA 1W Lamp #2: 276.3 of 4000 hours
Solar Diffuser Door: 1453 of 3022 Movements
Nadir Aperture Door: 532 of 1316 Movements
Space View Door: 437 of 1316 Movements
Email the MODIS IOT
to report any problem with the MODIS IOT Web Pages.
Email the MCST Webmaster
to report any problem with the MCST Web Pages.
Email the MCST Helpdesk
to ask a question about Level 1B usage, algorithms or software.