MAIN PAGEMODIS INFOINSTRUMENT OPSWeekly ReportsMODIS HistoryCALIBRATIONL1B PRODUCT INFO
|
MODIS IOT Terra Weekly Report
Mission Operations Days: 2000/323 to 2000/329
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Terra (AM-1) is in Normal Ops Mode MODIS is in Science Mode - B Side |
||
| Component | State(s) | Comment |
|---|---|---|
| Blackbody | A Off; B On (290 K) | Nominal |
| Calibration Electronics | A Off; B On | Nominal |
| Control Processor | A Off; B On | Nominal |
| Nadir Door | Unlatched, Open | Nominal |
| Space View Door | Unlatched, Open | Nominal |
| Solar Diffuser Door | Unlatched, Closed | Nominal |
| FDDI Formatter | A Off; B On | Nominal |
| FDDI Port | A On; B Off | Nominal |
| FIFO Memory | #1 & #2 Off; #3 & #4 On | Nominal |
| Format Processor | A Off; B On | Nominal |
| Power Supplies | #1 Off; #2 On | Nominal |
| PV VIS FPA | A Off; B On | Nominal |
| PV NIR FPA | A Off; B On | Nominal |
| PV SMIR FPA | A Off; B On | Nominal |
| PV LWIR FPA | A Off; B On | Nominal |
| PC LWIR FPA | A Off; B On | Nominal |
| RC Outgas Heaters | All Off (CS, IS, OS) | Nominal |
| RC LWIR FPA Heater | On (83 K) | Nominal |
| RC SMIR FPA Heater | Off | Nominal |
| Scan Assembly | A Off; B On | Nominal |
| SDSM | A Off; B Off | Nominal |
| SRCA | A Off; B Off | Nominal |
| PS1 Survival Heater | Enabled | Nominal |
| PS2 Survival Heater | Enabled | Nominal |
| Timing Generator | A Off; B On | Nominal |
| Flight Software | Rev BD + 1 set of patches
| Nominal |
| Inhibit Ids Set | None | Nominal |
| TMONs Enabled | 68 | Nominal |
Leonid Meteor shower Nov 17th & 18th: MODIS remained in nominal B-side science operations, however, all calibration activities were suspended during this time.
Saturday, November 18, 2000None
Sunday, November 19, 2000None
Monday, November 20, 2000
2000/325 21:00:00 ATC Set Blackbody to 270K
2000/326 15:00:00 ATC Set Blackbody to 280K
2000/326 19:00:00 ATC Set Blackbody to 285K
2000/326 21:00:00 ATC Set Blackbody to 290K
2000/326 23:00:00 ATC Set Blackbody to 295K
2000/326 23:01:00 ATC Set Blackbody duty cycle to FULL
2000/327 01:00:00 ATC Set Blackbody to 300K
2000/327 03:00:00 ATC Set Blackbody to 315K
2000/327 05:00:00 ATC Set Blackbody to 270K
2000/327 05:01:00 ATC Set Blackbody duty cycle to THIRD
2000/327 21:25:10 ATC OA15: SDSM Open
2000/327 23:04:03 ATC OA16: SDSM Screened
2000/328 01:00:00 ATC Set Blackbody to 290K
2000/328 09:48:37 - 10:22:10 ATC SRCA Full Radiometric (B)
2000/329 10:29:10 - 11:20:49 ATC SRCA Full Spectral 30W Part I (B)
2000/329 12:24:17 - 12:59:02 ATC SRCA Full Spectral 30W Part II (B)
2000/329 13:46:23 - 14:37:39 ATC SRCA Full Spectral 10W Part I (B)
2000/329 15:42:04 - 16:20:02 ATC SRCA Full Spectral 10W Part II (B)
None
None
Saturday, November 25, 2000None
Sunday, November 26, 2000None
Monday, November 27, 2000None
Tuesday, November 28, 2000None
Wednesday, November 29, 2000
2000/327 21:31:26 ATC OA15: SDSM Open
2000/327 23:10:19 ATC OA16: SDSM Screened
None
Friday, December 1, 2000None
None.
No formatter anomalies have been detected since switching to B-side science operations. The MODIS IOT is continuing to monitor changes with the radiative cooler temperatures and focal plane power.
MODIS is in Science Mode on the B-side with the SVD and NAD open, operating with the Formatter Resolution Flight Software Patches (FRFSP). No new events have been witnessed by the FRFSP since the B-Side Transition on DOY 2000/304.
The Radiative Cooler intermediate stage temperature has slowly been increasing since approximately DOY 2000/240. During this time the LWIR focal plane heater margin has been decreasing. The IOT is continuing to trend these telemetry mnemonics.
None.
SRCA 10W Lamp #1: 176.3 of 500 hours
SRCA 10W Lamp #2: 137.6 of 500 hours
SRCA 10W Lamp #3: 146.8 of 500 hours
SRCA 10W Lamp #4: 61.5 of 500 hours
SRCA 1W Lamp #1: 556.3 of 4000 hours
SRCA 1W Lamp #2: 276.3 of 4000 hours
Solar Diffuser Door: 1459 of 3022 Movements
Nadir Aperture Door: 532 of 1316 Movements
Space View Door: 437 of 1316 Movements
Email the MODIS IOT
to report any problem with the MODIS IOT Web Pages.
Email the MCST Webmaster
to report any problem with the MCST Web Pages.
Email the MCST Helpdesk
to ask a question about Level 1B usage, algorithms or software.